UES24LCP-SPA-OP

• Meets medical & I.T.E. safety

• 2 MOPP input to output isolation

• Touch current ≤ 100µA

• Energy efficiency level VI

• ≤ 0.075W standby power

• 6.1V-52V outputs, up to 24W

• Up to 5,000m operating altitude


Model NumberVoltage (V)Current (A)Rated Power Ripple & Noise (max)Voltage ToleranceLine & Load RegulationEfficiency (Average)Start Up Delay
UES24LCP-XXXYYYSPA-OP6.1-7.00.01-3.0021.00W120mVpk-pk±5%

Line:±1%

Load:±5%

86.20%≤3s
7.1-8.00.01-2.6221.00W120mVpk-pk±5%86.20%≤3s
8.1-9.00.01-2.3321.00W150mVpk-pk±5%86.20%≤3s
9.1-10.00.01-2.1021.00W150mVpk-pk±5%86.20%≤3s
10.1-11.00.01-2.1824.00W150mVpk-pk±5%87.00%≤3s
11.1-12.00.01-2.0024.00W150mVpk-pk±5%87.00%≤3s
12.1-13.00.01-1.8424.00W200mVpk-pk±5%87.00%≤3s
13.1-14.00.01-1.7124.00W200mVpk-pk±5%87.00%≤3s
14.1-15.00.01-1.6024.00W200mVpk-pk±5%87.00%≤3s
15.1-16.00.01-1.5024.00W200mVpk-pk±5%87.00%≤3s
16.1-17.00.01-1.4124.00W200mVpk-pk±5%87.00%≤3s
17.1-18.00.01-1.3324.00W200mVpk-pk±5%87.00%≤3s
18.1-19.00.01-1.2624.00W200mVpk-pk±5%87.00%≤3s
19.1-20.00.01-1.2024.00W240mVpk-pk±5%87.00%≤3s
20.1-21.00.01-1.1424.00W240mVpk-pk±5%87.00%≤3s
21.1-22.00.01-1.0924.00W240mVpk-pk±5%87.00%≤3s
22.0-23.00.01-1.0424.00W240mVpk-pk±5%87.00%≤3s
23.1-24.00.01-1.0024.00W240mVpk-pk±5%87.00%≤3s
45.1-46.00.01-0.5224.00W300mVpk-pk±5%87.00%≤3s
46.1-47.00.01-0.5124.00W300mVpk-pk±5%87.00%≤3s
47.1-48.00.01-0.5024.00W300mVpk-pk±5%87.00%≤3s
48.1-49.00.01-0.4824.00W300mVpk-pk±5%87.00%≤3s
49.1-50.00.01-0.4824.00W300mVpk-pk±5%87.00%≤3s 
50.1-51.00.01-0.4724.00W300mVpk-pk±5% 87.00%≤3s 
51.1-52.00.01-0.4624.00W300mVpk-pk±5%87.00%≤3s

1.jpg

Notes

(*1) Other options are available, please contact our sales representative for details.


Input Voltage Range

90-264VAC
Frequency Range 47-63Hz
Input Current0.5A at 90VAC
Inrush Current70A max at 240VAC cold start
Touch Leakage Current≤100μA at 264VAC

Dimensions(mm)

82(L)*64(W)*20.5(H)
Weight70g
MTBF>100,000hrs MIL-HDBK-217 at 25℃
Overload110-200% rated output power, auto recovery
Over Voltage120-150% rated output voltage input to reset
Short CircuitTrip and restart (hiccup mode)
Safety Agency / MarkMedicalITE
CB

IEC60601-1

IEC60950-1    
ULANSI/AAMI ES60601-1-
CAN/CSA C22.2 NO. 60601-1
EmissonsMedicalITE
ConductionIEC/EN 60601-1-2,CISPR 11EN55032, CISPR 32
RadiationIEC/EN 60601-1-2,CISPR 11EN55032, CISPR 32
Harmonic CurrentsEN61000-3-2, Class AEN61000-3-2, Class A
Voltage FlickerEN61000-3-3EN61000-3-3
ImmunityIEC/EN 60601-1-2EN55024, CISPR 24
Radiated ImmunityIEC61000-4-3

10V/m ,3V/m 80MHz - 2.7GMHz

EFT/BurstIEC61000-4-4±2KV on AC port, ±1KV on signal ports
SurgeIEC61000-4-5±1KV line to line (different mode)
Conducted ImmunityIEC61000-4-63Vrms, 6Vrms (0.15MHz-80MHz)
Magnetic FieldIEC61000-4-830 A/m

Dips & Interruptions

IEC61000-4-110%, 70%, 0% of UT
Dielectric Withstand Voltage

5,656VDC input to output

Insulation Resistance10M Ohms, 500VDC input to output